S-2.1, r. 9 - Regulation respecting concrete pumps and distribution masts

Full text
57. The owner of a pump-truck who supplies, leases or uses a pump-truck shall ensure that, in the following circumstances, the supporting members of the pump-truck undergo a non-destructive test carried out by a certified organization:
(1)  after the first 6,000 hours of use of a pump-truck following its manufacture or after the first 5 years of service, whichever comes first, and, thereafter, not less than once every 4,500 hours of use or once every 3 years, whichever comes first;
(2)  before a used pump-truck is put into service in Québec; and
(3)  after an abnormal stress or an incident necessitating an essential repair.
O.C. 1520-92, s. 57; O.C. 605-2014, s. 6.
57. The owner of a pump-truck who supplies, leases or uses a pump-truck shall ensure that, in the following circumstances, the supporting members of the pump-truck undergo a non-destructive test carried out by a certified organization which has certified inspectors in its service:
(1)  after the first 6,000 hours of use of a pump-truck following its manufacture or after the first 5 years of service, whichever comes first, and, thereafter, not less than once every 4,500 hours of use or once every 3 years, whichever comes first;
(2)  before a used pump-truck is put into service in Québec; and
(3)  after an abnormal stress or an incident necessitating an essential repair.
O.C. 1520-92, s. 57.